Controlling capillary pressure in concrete to prevent plastic shrinkage cracking

dc.contributor.advisorBoshoff, William P
dc.contributor.coadvisorSmit, Martha S
dc.contributor.emailstiaandeysel@gmail.comen_US
dc.contributor.postgraduateDeysel, Renier Christiaan
dc.date.accessioned2023-02-24T07:03:08Z
dc.date.available2023-02-24T07:03:08Z
dc.date.created2023
dc.date.issued2022
dc.descriptionDissertation (MEng(Structural Engineering))--University of Pretoria,2022en_US
dc.description.abstractPlastic shrinkage cracking occurs in concrete members with large exposed surface areas, such as concrete pavements, bridge decks and floor slabs. Current research has shown that a notable increase in plastic shrinkage was observed in the engineering practice, leading to considerably more cracking problems than in the past. Plastic shrinkage cracking occurs when the plastic shrinkage of fresh concrete is restrained, leading to tensile stresses, which result in cracks when the tensile strength is exceeded. Plastic shrinkage is caused by negative capillary pressure build-up in fresh concrete. Controlling the negative capillary pressure build-up makes it possible to reduce the risk of plastic shrinkage cracking. The aim of this study was to develop a model that uses live in-situ capillary pressure measurements in fresh concrete to control the capillary pressure build-up to prevent plastic shrinkage cracking at any evaporation rate. A model was developed that calculates a critical pressure limit for when an action is needed to prevent plastic shrinkage cracking. The model uses the negative capillary pressure build-up area between two crucial time points in plastic shrinkage to determine this limit. The proposed model was tested and verified in two phases. The testing and verification of the model were conducted on a low bleed concrete having a water/cement ratio of 0.5 and a self-compacting concrete with a water/cement ratio of 0.4. Tensiometers were used to measure the capillary pressure build-up in concrete. The first phase consisted of determining the parameters required for the model. The second phase used the determined parameters to test the model with the two concrete mixtures at various evaporation rates. The results showed that the model could determine a critical pressure limit relevant to the concrete and evaporation rate. The proposed model proved to be a valuable tool in controlling the capillary pressure and preventing plastic shrinkage cracking in low bleed and self-compacting concrete.en_US
dc.description.availabilityUnrestricteden_US
dc.description.degreeMEng(Structural Engineering)en_US
dc.description.departmentCivil Engineeringen_US
dc.identifier.citation*Deysel, RC 2022, Controlling capillary pressure in concrete to prevent plastic shrinkage cracking, MEng Dissertation, University of Pretoria, Pretoriaen_US
dc.identifier.doihttps://doi.org/10.25403/UPresearchdata.22083506en_US
dc.identifier.urihttps://repository.up.ac.za/handle/2263/89803
dc.language.isoenen_US
dc.publisherUniversity of Pretoria
dc.rights© 2022 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
dc.subjectPlastic Shrinkageen_US
dc.subjectPlastic Shrinkage Crackingen_US
dc.subjectFresh Concreteen_US
dc.subjectCapillary Pressureen_US
dc.subjectTensiometersen_US
dc.subject.otherEngineering, built environment and information technology theses SDG-09
dc.subject.otherSDG-09: Industry, innovation and infrastructure
dc.subject.otherEngineering, built environment and information technology theses SDG-11
dc.subject.otherSDG-11: Sustainable cities and communities
dc.subject.otherEngineering, built environment and information technology theses SDG-12
dc.subject.otherSDG-12: Responsible consumption and production
dc.subject.otherEngineering, built environment and information technology theses SDG-13
dc.subject.otherSDG-13: Climate action
dc.titleControlling capillary pressure in concrete to prevent plastic shrinkage crackingen_US
dc.typeDissertationen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Deysel_Controlling_2022.pdf
Size:
16.32 MB
Format:
Adobe Portable Document Format
Description:
Mini Dissertation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: