Implementation of continuous-wave Doppler ultrasound to detect the high-risk foetus in the low-risk mother : lessons from South Africa

Show simple item record

dc.contributor.author Hlongwane, T.M.A.G. (Tsakane)
dc.contributor.author Pattinson, Robert Clive
dc.contributor.author Bergh, Anne-Marie
dc.date.accessioned 2024-03-15T13:02:53Z
dc.date.available 2024-03-15T13:02:53Z
dc.date.issued 2023-05-27
dc.description DATA AVAILABILITY : All data generated or analysed during this study are included in this published article and its supplementary information files. en_US
dc.description.abstract INTRODUCTION : Detecting the risk of stillbirth during pregnancy remains a challenge. Continuous-wave Doppler ultrasound (CWDU) can be used to screen for placental insufficiency, which is a major cause of stillbirths in low-risk pregnant women. This paper describes the adaptation and implementation of screening with CWDU and shares critical lessons for further rollout. Screening of 7088 low-risk pregnant women with Umbiflow™ (a CWDU device) was conducted in 19 antenatal care clinics at nine study sites in South Africa. Each site comprised a catchment area with a regional referral hospital and primary healthcare antenatal clinics. Women with suspected placental insufficiency as detected by CWDU were referred for follow-up at the hospital. A 35–43% reduction in stillbirths was recorded. METHODS : The authors followed an iterative reflection process using the field and meeting notes to arrive at an interpretation of the important lessons for future implementation of new devices in resource-constrained settings. RESULTS : Key features of the implementation of CWDU screening in pregnancy combined with high-risk follow-up are described according to a six-stage change framework: create awareness; commit to implement; prepare to implement; implement; integrate into routine practice; and sustain practice. Differences and similarities in implementation between the different study sites are explored. Important lessons include stakeholder involvement and communication and identifying what would be needed to integrate screening with CWDU into routine antenatal care. A flexible implementation model with four components is proposed for the further rollout of CWDU screening. CONCLUSIONS : This study demonstrated that the integration of CWDU screening into routine antenatal care, combined with standard treatment protocols at a higher-level referral hospital, can be achieved with the necessary resources and available maternal and neonatal facilities. Lessons from this study could contribute to future scale-up efforts and help to inform decisions on improving antenatal care and pregnancy outcomes in low- and middle-income countries. en_US
dc.description.department Obstetrics and Gynaecology en_US
dc.description.librarian am2024 en_US
dc.description.sdg SDG-03:Good heatlh and well-being en_US
dc.description.sponsorship The South African Medical Research Council through its Division of Research Capacity Development under the SAMRC Institutional Clinician Researcher Programme. en_US
dc.description.uri https://bmcpregnancychildbirth.biomedcentral.com en_US
dc.identifier.citation Hlongwane, T.M.A.G., Pattinson, R.C., Bergh, A.-M. 2023, 'Implementation of continuous-wave Doppler ultrasound to detect the high-risk foetus in the low-risk mother : lessons from South Africa', BMC Pregnancy and Childbirth, vol. 23, art. 393, pp. 1-12. https://DOI.org/10.1186/s12884-023-05721-3. en_US
dc.identifier.issn 1471-2393
dc.identifier.other 10.1186/s12884-023-05721-3
dc.identifier.uri http://hdl.handle.net/2263/95237
dc.language.iso en en_US
dc.publisher BMC en_US
dc.rights © The Author(s) 2023. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License. en_US
dc.subject Placental insufficiency en_US
dc.subject Stillbirths en_US
dc.subject Stages of change en_US
dc.subject Implementation of screening en_US
dc.subject Antenatal care (ANC) en_US
dc.subject SDG-03: Good health and well-being en_US
dc.subject Continuous-wave Doppler ultrasound (CWDU) en_US
dc.title Implementation of continuous-wave Doppler ultrasound to detect the high-risk foetus in the low-risk mother : lessons from South Africa en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record