Using shear modulus to predict the bearing capacity of strip foundations on sand

dc.contributor.authorMurison, Ruan A.
dc.contributor.authorHeymann, Gerhard
dc.contributor.emailruan.murison@tuks.co.zaen_US
dc.date.accessioned2025-03-05T07:17:16Z
dc.date.available2025-03-05T07:17:16Z
dc.date.issued2024-07
dc.descriptionThe paper was published in the Proceedings of the 8th International Symposium on Deformation Characteristics of Geomaterials ( IS- PORTO 2023) and was edited by António Viana da Fonseca and Cristiana Ferreira. The symposium was held from the 3rd to the 6th of September 2023 in Porto, Portugal.en_US
dc.description.abstractThis paper reports results of a study to predict load-settlement behaviour of strip foundations on a dry uncemented sand using only soil stiffness data, under both working loads and extreme loads. This involved predicting the strength of a foundation system without using any strength parameters. A non-linear stepwise load-settlement prediction algorithm was utilised, which used the small-strain shear modulus of layers below the footing, a suitable stiffness modulus reduction curve and elasticity theory. The algorithm was adapted to predict the ultimate bearing capacity, as well as to construct a stress-settlement curve and determine the bearing pressure experienced beneath a foundation at any particular settlement. The method was evaluated using two different sets of modulus reduction curves, for small-scale model foundations on loose, medium dense and dense sand. Model tests were conducted at 1g. Particle Image Velocimetry (PIV) was used to observe strains within the soil during loading. These strains were used to calculate the shear modulus of discrete layers throughout loading and back-estimate the layer small-strain shear moduli. Additionally, the mode of shear failure for each test at ultimate bearing capacity was observed using PIV. Modulus reduction curves that initially degrade shear modulus rapidly beyond the elastic threshold strain (0.001%) gave superior predictions under the given conditions. Using such curves, ultimate bearing capacity predictions produced errors of 0.4% to 10.8%. Using the same input parameters, stresssettlement predictions were of satisfactory accuracy over the entire settlement range.en_US
dc.description.departmentCivil Engineeringen_US
dc.description.librarianam2024en_US
dc.description.sdgSDG-09: Industry, innovation and infrastructureen_US
dc.description.urihttps://www.e3s-conferences.org/en_US
dc.identifier.citationMurison, R.A. & Heymann, G. 2024, 'Using shear modulus to predict the bearing capacity of strip foundations on sand', E3S Web of Conferences, vol. 544, art. 07005, pp. 1-9, doi : 10.1051/e3sconf/202454407005.en_US
dc.identifier.doi10.1051/e3sconf/202454407005
dc.identifier.issn2267-1242
dc.identifier.urihttp://hdl.handle.net/2263/101339
dc.language.isoenen_US
dc.publisherEDP Sciencesen_US
dc.rights© 2024 EDP Sciences.en_US
dc.subjectShear modulusen_US
dc.subjectShallow foundationsen_US
dc.subjectModulus reduction curvesen_US
dc.subjectDigital image correlationen_US
dc.subjectSDG-09: Industry, innovation and infrastructureen_US
dc.titleUsing shear modulus to predict the bearing capacity of strip foundations on sanden_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Murison_Using_2024.pdf
Size:
1.48 MB
Format:
Adobe Portable Document Format
Description:
Conference paper

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: