Experimental investigation of heat transfer during LOCA with failure of emergency cooling system

dc.contributor.authorNandan, Gopal
dc.contributor.authorLele, H.G.
dc.contributor.authorSahoo, P.K.
dc.contributor.authorChatterjee, B.
dc.contributor.authorKumar, Ravi
dc.contributor.authorMukhopadhyay, D.
dc.date.accessioned2015-06-11T10:53:54Z
dc.date.available2015-06-11T10:53:54Z
dc.date.issued2007
dc.description.abstractPaper presented at the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July, 2007.en_ZA
dc.description.abstractThe pressure tubes (PT) in the Indian Pressurized Heavy Water Reactor (PHWR) are kept concentrically inside horizontal calandria tube (CT), which is submerged in a moderator pool. During postulated loss-of-coolant accident (LOCA) without emergency core cooling system, the temperature of PT could rise significantly. At elevated temperature, the weight of the PT with the weight of fuel pins could cause it to sag. Before sagging heat transfer from the PT to CT is mainly by convection. Once the PT sags and touches the CT, heat transfer mode changes to conduction. Direct contact between the PT and CT increases heat transfer and checks the temperature rise of the PT and limit the fuel heatup and subsequent degradation of the reactor core. An experimental set-up is designed and fabricated at Indian Institute of Technology Roorkee (IITR) to simulate the LOCA in the Indian PHWR. From the experimental investigation, it is found that the contact between the PT and CT occurred at around 300 seconds after the initiation of the simulation with corresponding temperature of the PT at around 680°C. The experiment was continued after the contact between the PT and CT and it is found that the temperature rise of the PT was within 800°C. This work demonstrates the inherent safety feature of Pressurised Heavy Water Reactor.en_ZA
dc.description.librariancs2014en_ZA
dc.format.extent5 pagesen_ZA
dc.format.mediumPDFen_ZA
dc.identifier.citationNandan, G, Lele, HG, Sahoo, PK, Chatterjee, B, Kumar, R & Mukhopadhyay, D 2007, 'Experimental investigation of heat transfer during LOCA with failure of emergency cooling system', Paper presented to the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July 2007.en_ZA
dc.identifier.isbn9781868546435
dc.identifier.urihttp://hdl.handle.net/2263/45468
dc.language.isoenen_ZA
dc.publisherInternational Conference on Heat Transfer, Fluid Mechanics and Thermodynamicsen_ZA
dc.relation.ispartofHEFAT 2007
dc.rightsUniversity of Pretoriaen_ZA
dc.rights.uriUniversity of Pretoriaen_US
dc.subjectPressure tubesen_ZA
dc.subjectIndian pressurized heavy water reactoren_ZA
dc.subjectCalandria tubeen_ZA
dc.subjectLoss-of-coolant accidenten_ZA
dc.subjectHeat transferen_ZA
dc.subjectIndian Institute of Technology Roorkeeen_ZA
dc.subjectPressurised Heavy Water Reactoren_ZA
dc.titleExperimental investigation of heat transfer during LOCA with failure of emergency cooling systemen_ZA
dc.typePresentationen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nandan_Experimental_2014.pdf
Size:
113.16 KB
Format:
Adobe Portable Document Format
Description:
Presentation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: