Analytical and quality control validation of a novel symmetric dimethylarginine assay in dogs and cats
dc.contributor.author | Mashego, Portia Tshidi | |
dc.contributor.author | Hooijberg, Emma Henriette | |
dc.date.accessioned | 2025-09-26T09:20:49Z | |
dc.date.available | 2025-09-26T09:20:49Z | |
dc.date.issued | 2025-09 | |
dc.description.abstract | BACKGROUND : An immunoturbidometric assay for symmetric dimethylarginine (SDMA) measurement on automated chemistry analyzers has recently become available. OBJECTIVE : To perform analytical validation of the EUROLyser SDMA assay in dogs and cats. METHODS : Method validation experiments were performed using stored canine and feline serum. Quality control validation was performed according to Westgard. Performance goals were derived from SDMA biological variation data for both species. RESULTS : Imprecision ranged from 3.7%-7.8% (dogs) to 6.0%-11.8% (cats) with a dispersion of ±35% for dogs and ±44% for cats. The assay showed linearity (up to 85 μg/dL [dogs], 75 μg/dL [cats]); the preliminary LoQ was 9.5 and 6.9 μg/dL, respectively. Recovery was 19.7% and 6.5%, respectively. Severe hemolysis resulted in a significant bias in both species. The EUROLyser method showed a significant negative proportional and constant bias in dogs and a significant positive proportional and negative constant bias in cats, compared to the comparative method. In dogs, the mean bias (-19.5%) and the bias at clinical decision limits exceeded the desirable bias; in cats, the mean bias (-4.0%) and the bias at clinical decision limits was < 8%. Because of high imprecision, the TEA that could be controlled for was 35%, with a 1-2.5 s rule using patient pools as quality control material. CONCLUSIONS : The novel SDMA assay showed acceptable analytical performance, but high dispersion has consequences for the interpretation of results at reference limits and serial measurements. Method-specific reference intervals and decision limits should be generated for both species, particularly for dogs, given the significant bias vs. the comparative method. | |
dc.description.department | Companion Animal Clinical Studies | |
dc.description.librarian | hj2025 | |
dc.description.sdg | SDG-03: Good health and well-being | |
dc.description.sponsorship | AgriSETA, Department of Higher Education and Training, South Africa. | |
dc.description.uri | https://onlinelibrary.wiley.com/journal/1939165x | |
dc.identifier.citation | Mashego, P.T. & Hooijberg, E.H. 2025, 'Analytical and quality control validation of a novel symmetric dimethylarginine assay in dogs and cats', Veterinary Clinical Pathology, vol. 54, no. 3, pp. 239-250, doi : 10.1111/vcp.70037. | |
dc.identifier.issn | 0275-6382 (print) | |
dc.identifier.issn | 1939-165X (online) | |
dc.identifier.other | 10.1111/vcp.70037 | |
dc.identifier.uri | http://hdl.handle.net/2263/104512 | |
dc.language.iso | en | |
dc.publisher | Wiley | |
dc.rights | © 2025 The Author(s). Veterinary Clinical Pathology published by Wiley Periodicals LLC on behalf of American Society for Veterinary Clinical Pathology. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License. | |
dc.subject | Symmetric dimethylarginine (SDMA) | |
dc.subject | Creatinine | |
dc.subject | Dispersion | |
dc.subject | Method validation | |
dc.subject | Quality control validation | |
dc.title | Analytical and quality control validation of a novel symmetric dimethylarginine assay in dogs and cats | |
dc.type | Article |