Heat transfer coefficient characterization at the solar collector wall-fluid interface

dc.contributor.authorMébarki, Ghazali
dc.contributor.authorRahal, Samir
dc.date.accessioned2015-08-25T10:30:26Z
dc.date.available2015-08-25T10:30:26Z
dc.date.issued2015
dc.description.abstractPaper presented to the 3rd Southern African Solar Energy Conference, South Africa, 11-13 May, 2015.en_ZA
dc.description.abstractIn this paper, a numerical study is carried out to characterize the transient local heat transfer coefficient at the fluid-solid wall interface of a solar collector. For that purpose, the considered collector wall geometry is a flat plate with nonnegligible thickness which is subjected to a variable solar heat flux. The transient conjugated conduction-convection heat transfer has been taken into account. The heat transfer coefficient is calculated as a function of the plate thickness as well as the position along the plate. A good agreement has been found between the calculated temperatures and other experimental results. The heat transfer coefficient evolutions, as a function of time, have been obtained for various positions along the plate. The results showed that at first, high values of the heat coefficient are reached, and then it decreases and tends to constant values. It has been also noticed that at a fixed value of time, the heat transfer decreases when the position is increased from the beginning of the plate towards its end. The parametric study allowed obtaining a correlation of the transient convective heat transfer coefficient as a function of the steady state coefficient (which depends on the flow velocity and the coordinate of the considered point on the plate), multiplied by a function of time and the plate properties. The results have been used to optimize the heat transfer coefficient measurement technique using the pulse method. The pulse method consists in imposing a heat flux on a wall, and then to calculate, by an inverse method, the heat transfer coefficient from the time evolution of surface temperature (thermo-gram). Measurement of the heat transfer coefficient is based on the introduction into the inverse model of a function that represents the theoretical evolution of this coefficient due to the energy excitation. This function is deduced from the numerical study conducted in this work.en_ZA
dc.description.librariandc2015en_ZA
dc.format.extent6 pagesen_ZA
dc.format.mediumPDFen_ZA
dc.identifier.citationMébarki, G. & Rahal, S. 2015, 'Heat transfer coefficient characterization at the solar collector wall-fluid interface', Paper presented to the 3rd Southern African Solar Energy Conference, South Africa, 11-13 May, 2015.en_ZA
dc.identifier.urihttp://hdl.handle.net/2263/49578
dc.language.isoenen_ZA
dc.publisher3rd Southern African Solar Energy Conference, South Africa, 11-13 May, 2015.en_ZA
dc.rights© 2015 University of Pretoriaen_ZA
dc.subjectLocal heat transfer coefficienten_ZA
dc.subjectFluid-solid wallen_ZA
dc.subjectSolar collectorsen_ZA
dc.subjectSolar heat fluxen_ZA
dc.subjectHeat transfer coefficienten_ZA
dc.titleHeat transfer coefficient characterization at the solar collector wall-fluid interfaceen_ZA
dc.typePresentationen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mebarki_Heat_2015.pdf
Size:
673.35 KB
Format:
Adobe Portable Document Format
Description:
Presentation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: