Effect of cooling rate on improving the performance of the catalytic PVC reactor in Egyptian petrochemical company

Show simple item record

dc.contributor.author El-Shazly, AH
dc.contributor.author Elsayed, OS
dc.date.accessioned 2015-04-23T12:09:34Z
dc.date.available 2015-04-23T12:09:34Z
dc.date.issued 2014
dc.description.abstract Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014. en_ZA
dc.description.abstract This work investigates the possibility of improving the performance of poly vinyl chloride (PVC) reactor in Egyptian Petrochemical Company (EPC) by enhancing the rate of heat transfer via increasing the cooling rate of the reactant. Two booster pumps have been installed for the four reactors to increase the flow rate of the cooling water in the reactor jacket by a factor of 1.25. Different cooling rates were investigated under different batches of the process. In addition a comparison between theoretical and actual results obtained was carried out. It was found that increasing the cooling rate has increased the PVC productivity of each batch to 23.3 ton/batch by a percentage of 115% of the design capacity; Decreasing the time of the reaction from 6 hr to 4.5 hr. The overall capacity of PVC plant increased by 25% more than the design capacity. In addition a reduction in the operation hours of the agitators i.e saving in energy consumption; Finally increasing the lifetime of the reactor by reducing the frequency of the process of chemical cleaning that has side effect on the reactor life time. en_ZA
dc.format.medium PDF en_ZA
dc.identifier.citation El-Shazly, AH, Elsayed, OS 2014, 'Effect of cooling rate on improving the performance of the catalytic PVC reactor in Egyptian petrochemical company', Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014. en_ZA
dc.identifier.isbn 97817759206873
dc.identifier.uri http://hdl.handle.net/2263/44623
dc.publisher International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics en_ZA
dc.rights © 2014 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. en_ZA
dc.subject PVC reactor en_ZA
dc.subject Performance improvement en_ZA
dc.subject Cooling rates en_ZA
dc.title Effect of cooling rate on improving the performance of the catalytic PVC reactor in Egyptian petrochemical company en_ZA
dc.type Presentation en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record